Aspro IODM 115, due to their simple functioning and high performanceare the ideal solution for high capacity refueling stations, guranteeing a quick, efficient and safety CNG refilling.
- Inlet pressure; 0,2 to 60 bar (2,9 to 870 PSI)
- Flow: 369 to 2500 Nm³/h (217 to 1471 SCF/m)
- Horizontal reciprocating of 2 / 3 / 4 / 5 stages
- Driven belt transmission
- Electric motor
- Power: 110 / 200 kW (150 / 270 HP)
- Air cooled
- Lubrication system
- Last compression stage condensers
IODM 115 | 2-25 | 2-30 | 3-12 | 3-16 | 3-19 | 4 | 4R | 4RE | 4RR | 5-3-12 | 5-3-16 | 5-3-19 | 5-4R | 5-4RE | 5-15 |
Type | Horizontal Reciprocating | ||||||||||||||
Number of stages |
2
|
3
|
4
|
5
|
|||||||||||
Max. suction pressure (bar) |
35 bar
(507,6 PSI) |
60 bar
(870 PSI) |
13 bar
(188,5 PSI) |
17 bar
(246,5 PSI) |
19 bar
(275,5 PSI) |
8 bar
116 PSI) |
6 bar
(87 PSI) |
6 bar
(87 PSI) |
3 bar
(43,5 PSI) |
3,25 bar
(3,25 PSI) |
6 bar
(6 PSI) |
3 bar
(3 PSI) |
1,5 bar
(1,5 PSI) |
1,2 bar
(1,2 PSI) |
9 bar
(9 PSI) |
Min. suction pressure n (bar) |
18 bar
(261 PSI) |
20 bar
(290 PSI) |
7 bar
(101.5 PSI) |
14 bar
(203 PSI) |
12 bar
(174 PSI) |
4 bar
(58 PSI) |
2 bar
(29 PSI) |
2 bar
(29 PSI) |
1,4 bar
(20.3 PSI) |
1,75 bar
(25.375 PSI) |
1,25 bar
(18.13 PSI) |
7 bar
(101.5 PSI) |
0,2 bar
(2,9 PSI) |
0,4 bar
(5.8 PSI) |
15 bar
(217.15 PSI) |
Discharge pressure (bar) | 250-300 bar (3625-4350 PSI) | ||||||||||||||
Stroke (mm) | 115 | ||||||||||||||
Pre-compressor power | 5,5 / 7,5 / 11 kW | ||||||||||||||
Main motor power |
90 / 160 kW
110 / 132 / 160 / 200 kW (150 / 177 / 220 / 270 HP) |
||||||||||||||
Air-cooler power | 5,5 / 7,5 / 11 Kw | ||||||||||||||
Voltage – Frequency | 380 / 440 vca – 50 / 60 hz | ||||||||||||||
Speed (RPM) | 800 / 900 / 1.000 |